When using traditional gravity tankers (tenders) in a shuttle operation, the sometimes "tricky" question is, "When do we to stop dumping water and go for another load." Ideally - each tanker should have a pre-determined "critical dump time" at which point the operator stops dumping. When using a 10-inch Newton-style dump, another reasonable rule of thumb is to stop dumping when the water drops below the 2-inch point on the chute - close the valve - and go get another load of water. Of course - this really depends on whether or not another tanker is in line waiting to get into position to dump.
The worst decision is to wait until the water is just trickling out of the dump chute. Remember that a tanker shuttle is best served when units are moving in the shuttle and not waiting to offload every last drop of water.
Looking good! Keep off-loading!
Still looking good - but start thinking about the point at which you are going to close the valve and head for another load of water.
Not looking so good! This tanker should have been on the road way before this point in the dumping process! Waiting for the last drop to come out actually lowers a tanker's delivery rate in the shuttle.