Drafting Tip #06 - Use Dual Suctions to Increase Pump Capacity

Print this story (opens in a new tab)News RSS feed (opens in a new tab)Share on Facebook (opens in a new window)Share on X (opens in a new window)Add a comment

By President Mark Davis
July 31, 2014

A very good way to increase the pump capacity of pumper (one that is rated 1500 gpm or less) is to draft using two suction inlets. Pumpers that have midship mounted pumps rated 1,500 gpm or less are usually rated using only one of their side suction inlets. By using both suction inlets, capacity can be significantly increased as long as the motor can produce sufficient torque to drive the pump. For example, a Hale Q-Max 1,500 gpm pump powered by a 500 hp motor can flow in excess of 2,200 gpm from draft using dual suctions. Once again, this reinforces the value of carrying additional suction hose and strainers on a pumper that serve rural communities.

Website Designed and Hosted By: Content Proudly Maintained By: Contact Info:
Firehouse Solutions
www.FirehouseSolutions.com
GBW Associates, LLC
3178 Cardinal Drive
Westminster, MD 21157

Emergency Dial 911
Phone: 443-398-6619
E-mail: thebigcamel@gotbigwater.com
Copyright © 2026 Firehouse Solutions (A Service of Technology Reflections, Inc.)